    1. All: 80 Hz continuous calibration. Update the table: https://deki.mpifr-bonn.mpg.de/Working_Groups/EVN_TOG/Continuous_calibration_%2880_Hz%29  The "last update" column is to be updated to allow correct session setups in VEX/pySCHED.

      Gonzáles:integrate atm into the FieldSystem 

      . 

    2. Bach: look at EHT station set-up document and see if it could be modified for use in the EVN. Create a master check list

    3. Bach, Himwich: investigate Investigate how to improve opacity and Tsys measurements at high frequencies in the Field System by incorporating the howTsys and opacity are determined at K band and higher at stations. Discussion continues on Mattermost.   atm software
    4. Bach compare gnplt opacity estimation versus WVR measurement.
    5. Poppi, Stagni:Set up sftp server on vlbeer (Stagni), setup discussion where to host server (Poppi). 

    ...

    Version from 16:51, 23 Jun 2024

    This revision modified by sergio.poppi (Ban)

    ...

    1. All: 80 Hz continuous calibration. Update the table: https://deki.mpifr-bonn.mpg.de/Working_Groups/EVN_TOG/Continuous_calibration_%2880_Hz%29  The "last update" column is to be updated to allow correct session setups in VEX/pySCHED.

    2. Gonzáles:integrate atm into the FieldSystem.

    3. Bach: look at EHT station set-up document and see if it could be modified for use in the EVN. Create a master check list

    4. Bach: investigate how Tsys and opacity are determined at K band and higher at stations. Discussion continues on Mattermost.

       

    5. Bach compare gnplt opacity estimation versus WVR measurement.

       

    Version as of 17:07, 23 Jun 2024

    This revision modified by sergio.poppi (Ban)

    ...

    1. All: 80 Hz continuous calibration. Update the table: https://deki.mpifr-bonn.mpg.de/Working_Groups/EVN_TOG/Continuous_calibration_%2880_Hz%29  The "last update" column is to be updated to allow correct session setups in VEX/pySCHED.

       

       

    2. Bach: look at EHT station set-up document and see if it could be modified for use in the EVN. Create a master check list

    3. Bach, HimwichInvestigate how to improve opacity and Tsys measurements at high frequencies in the Field System by incorporating the atm software
    4. Bach compare gnplt opacity estimation versus WVR measurement
    5. Poppi, Stagni:Set up sftp server on vlbeer (Stagni), setup discussion where to host server (Poppi). 

    ...