Table of contents
Pre-Checks
- Check that the 1pps is connected to all R2DBE units (frontside)
- Check that the IFs are connected to the Block Down Converter (BDC) with RCP and LCP as labeled on the backside
- Check that the 10MHz signal is connected to the clock synthesizer unit
- Check that the 10MHz signal is connected to the BDC unit
- Check that the both IF input pins of all R2DBE units (frontside) are connected by cable
- Check that all R2DBE units are connected by ethernet (PPC net port) to the network hub box (backside)
- Check that the noise generator unit is connected by ethernet to the network hub box (backside)
- Check that all mark6 units are connected by ethernet cable to the the network hub box (backside)
- In case you want to inspect the R2DBEs autocorrelation spectra make sure you insert a tone into the noise generator unit (backside)
Startup sequence
- power on the clock synthesizer unit
- power on the BDC
- power on the noise generator
- power on the R2DBEs
System verification
- log into pv-mark6-1 as user oper. Verify that all the R2DBEs units have booted up by trying an ssh connection:
ssh r2dbe-1 -l root ssh r2dbe-2 -l root ...
if one of the units does not boot consult the Troubleshooting section below.
Configuring the R2DBEs
- log-into pv-mark6-1 as user oper
- initialize all the R2DBE units by running:
start-r2dbe-1 start-r2dbe-2 ...