FPT Test Nov 2022

This page can't be edited. | Page History
    Table of contents
    You are currently comparing two old versions - only when you are comparing against the latest version can you revert. Return to version archive.

    Combined revision comparison

    Comparing version 20:33, 17 Jan 2024 by rottmann with version 20:35, 17 Jan 2024 by rottmann.

    ...

    Target band: 215.000 - 216.024214.052 - 216.100

    1st LO:     221.010221.052 GHz

    ...

    2nd LO (DBBC3): 8.0589.048 GHz

    Sky freq:    211.962 - 216.058212.004 - 216.100 GHz
     

    sky 212952212.004-214.052 213976214.052-216.100 215000 216024
    after 1st DC 80589.048 - 7.000 70347.000 - 4.952 6010 4986
    after 2nd DC 0 - 2.048 1024 20482.048 - 4.096 3072

    ...

    • load normally the OCT_120 firmware
    • run dbbc3ctl.py and do check system all
    • run /home/oper/rottmann/dbbc3/utilities/setupFPT.py dbbc3  (sets the 1GHz filters and the LO freqs)

    ...

    slot 1: fill VSNEHT%0017

    slot 2: fill VSNEHT%0018

    ...

    slot 1: fill VSNEHT%0019

    slot 2: fill VSNEHT%0020

    ...

    Version from 20:33, 17 Jan 2024

    This revision modified by rottmann (Ban)

    ...

    Target band: 214.052 - 216.100

    1st LO:     221.052 GHz

    ...

    2nd LO (DBBC3): 9.048 GHz

    Sky freq:    212.004 - 216.100 GHz
     

    sky 212.004-214.052 214.052-216.100
    after 1st DC 9.048 - 7.000 7.000 - 4.952
    after 2nd DC 0 - 2.048 2.048 - 4.096

    ...

    slot 1: fill VSN

    slot 2: fill VSN

    ...

    slot 1: fill VSN

    slot 2: fill VSN

    ...

    Version as of 20:35, 17 Jan 2024

    This revision modified by rottmann (Ban)

    ...

    Target band: 215.000 - 216.024

    1st LO:     221.010 GHz

    ...

    2nd LO (DBBC3): 8.058 GHz

    Sky freq:    211.962 - 216.058 GHz
     

    sky 212952 213976 215000 216024
    after 1st DC 8058 7034 6010 4986
    after 2nd DC 0 1024 2048 3072

    ...

    • load normally the OCT_120 firmware
    • run dbbc3ctl.py and do check system all
    • run /home/oper/rottmann/dbbc3/utilities/setupFPT.py dbbc3  (sets the 1GHz filters and the LO freqs)

    ...

    slot 1: EHT%0017

    slot 2: EHT%0018

    ...

    slot 1: EHT%0019

    slot 2: EHT%0020

    ...