Table of contents
Pre-Checks
- Check that the 1pps is connected to the DBBC2
- Check that the 10MHz is connected to the DBBC2
- Check that the IFs are connected (see Pico_DBBC.jpg )
- Check that the serial cable is connected to the FiLA10G box
- Check that the USB cable from the DBBC2 backside is NOT connected to the FiLA10G box
- Check that all 3 VSI cables are connected to the FiLA10G box (2 coming from the DBBC2, one going to the Mark5B)
- Check that one VSI cable of the FiLA10G box is connected to the Mark5 recorder
Startup
- power on the DBBC2 electronics (EL switch)
- power on the DBBC2 PC (PC swich)
- power on the FiLA10G box
Loading the DBBC2 firmware
- Log into the DBBC2 (user dbbc, password: ask Salvador/Helge); can be done also via remote desktop from mrt-vlbi
- Depending on the observation mode (PFB, or DDC) there are two different firmwares to be loaded:
- Polyphase Filterbank Mode (PFB)
On the desktop double-click: "DBBC2 Control PFB v16..." icon (exact name can vary depending on the version)
- Tunable Mode (DDC)
On the desktop double-click: "DBBC2 Control DDC v105..." icon (exact name can vary depending on the version)