MG004

    Version as of 15:22, 9 Nov 2024

    to this version.

    Return to Version archive.

    View current version

    MG004 Correlation Report

    General information

    Current Status

    Correlation finished, data is ready to be released.

    Fringes

    Station Code Fringes Plots Comments
    Ef B yes

    Fringe overview (including all of C181D) of all baselines including Ef in LL (left for each baseline) and RR (right for each baseline). Legend: white - scheduled, but no data, blue - no fringe, red-green - fringes of different quality. D -- fourfit error, in this case due to mixing upper and lower subbands in the KVN compatibility mode, no real problem with the data.

    Scans 18-20, 24-26, 28-29, 31, 33, 35-36 are missing from all diagnostic plots due to a difx2mark4 error. They are present in the final correlation products.

    c181d_FRINGE_RfAnt_Ef_LLRR_AllSrc.pdf

    Examples of fourfit fringe plots:

    Same for all antennas below unless otherwise noted.

    in the plots Ef is "missing" all the baselines except to ALMA, GLT and KVN. This is due to a fourfit error, the baselines are missing only from some of the diagnostic plots, but are present in the final correlation products.
    On X yes c181d_FRINGE_RfAnt_On_LLRR_AllSrc.pdf in the plots On is "missing" all the baselines except to ALMA, GLT and KVN. This is due to a fourfit error, the baselines are missing only from some of the diagnostic plots, but are present in the final correlation products.
    Ys Y yes c181d_FRINGE_RfAnt_Ys_LLRR_AllSrc.pdf in the plots Ys is "missing" all the baselines except to ALMA, GLT and KVN. This is due to a fourfit error, the baselines are missing only from some of the diagnostic plots, but are present in the final correlation products.
    Mh Z yes c181d_FRINGE_RfAnt_Mh_LLRR_AllSrc.pdf in the plots Mh is "missing" all the baselines except to ALMA, GLT and KVN. This is due to a fourfit error, the baselines are missing only from some of the diagnostic plots, but are present in the final correlation products.
    Pv P yes c181d_FRINGE_RfAnt_Pv_LLRR_AllSrc.pdf in the plots Pv is "missing" all the baselines except to ALMA, GLT and KVN. This is due to a fourfit error, the baselines are missing only from some of the diagnostic plots, but are present in the final correlation products.
    VLBA: Br b yes c181d_FRINGE_RfAnt_Br_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    VLBA: Fd f yes c181d_FRINGE_RfAnt_Fd_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    VLBA: Kp k yes c181d_FRINGE_RfAnt_Kp_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    VLBA: La l yes c181d_FRINGE_RfAnt_La_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    VLBA: Mk m yes c181d_FRINGE_RfAnt_Mk_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    VLBA: Nl n yes c181d_FRINGE_RfAnt_Nl_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    VLBA: Ov o yes c181d_FRINGE_RfAnt_Ov_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    VLBA: Pt p yes c181d_FRINGE_RfAnt_Pt_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    GBT: Gb G yes c181d_FRINGE_RfAnt_Gb_LLRR_AllSrc.pdf Baselines to EVN stations are "missing" due to a fourfit error. They are present in the final correlation products.
    GLT: Gl g yes c181d_FRINGE_RfAnt_Gl_LLRR_AllSrc.pdf  
    ALMA: Aa A yes

    c181d_FRINGE_RfAnt_Aa_LLRR_AllSrc.pdf

    ____________________________________________________________________

     
    KVN: Kt t yes c181d_FRINGE_RfAnt_Kt_LLRR_AllSrc.pdf  
    KVN: Ku u yes c181d_FRINGE_RfAnt_Ku_LLRR_AllSrc.pdf  
    KVN: Ky y yes c181d_FRINGE_RfAnt_Ky_LLRR_AllSrc.pdf  

     

    Notes

    There were problems with some diagnostic plots of this experiment due to yet poorly understood errors of fourfit and other HOPS components. But this does not change the quality of the final correlation product.

    Post-Correlation checks

    Residuals

    FITS completeness (pclist)