Table of contents
- 1. 2011 July 1
- 1.1.1.1.1. 1) Check problematic RCU
- 1.1.1.1.2. 2) LBA tests
2011 July 1
K. Schlich and A. Horneffer did the following:
1) Check problematic RCU
As seen on June 30the tile 64/65 was not working properly, because RCU 64 did not provide the neccessary power.
We tested the impedance of the cables to tile 64/65 and 70/71: 64: 200 kOhm, 65: 21 kOhm, 70: 240 kOhm, 71: 24 kOhm
On removing RCU 65, the half-lit LED on RCU 64 went off. Measuring the output voltage on then gave the correct results, and the tile 64/65 worked. We also replaced the RCU 65 with a new board, for this we had to remove the current limiting NTC/varistor(?) on the new RCU module to place and connect the HBA modem.
All tests afterward (modemtest and spectrum check with rspctl) were successfull afterward.
RCU modules now in place:
64: -> 10638002067
65: -> 10638002051
RCUs to return:
broken with high ADC noise: 10638001026
were at some point at position 64 and did not provide power to the HBA tile: 10638002049, 10638002087, 10638002001
2) LBA tests
A quick check of the spectra of the LBAs gave the following results:
RCU | Problem | RCU | Problem | RCU | Problem |
---|---|---|---|---|---|
8: | low signal | 12: | low signal | 44: | low signal |
8: low signal
12: low signal