07 July

    Table of contents

    Version as of 15:36, 22 Jul 2024

    to this version.

    Return to Version archive.

    View current version

    2011 July 1

    K. Schlich and A. Horneffer did the following:

    1) Check problematic RCU

    As seen on June 30the tile 64/65 was not working properly, because RCU 64 did not provide the neccessary power.

    We tested the impedance of the cables to tile 64/65 and 70/71: 64: 200 kOhm, 65: 21 kOhm, 70: 240 kOhm, 71: 24 kOhm

    On removing RCU 65, the half-lit LED on RCU 64 went off. Measuring the output voltage on then gave the correct results, and the tile 64/65 worked. We also replaced the RCU 65 with a new board, for this we had to remove the current limiting NTC/varistor(?) on the new RCU module to place and connect the HBA modem.

    All tests afterward (modemtest and spectrum check with rspctl) were successfull afterward.

    RCU modules now in place:

    64: -> 10638002067

    65: -> 10638002051

    RCUs to return:

    broken with high ADC noise: 10638001026

    were at some point at position 64 and did not provide power to the HBA tile: 10638002049, 10638002087, 10638002001

    2) LBA tests

    A quick check of the spectra of the LBAs gave the following results:

    RCU Problem RCU Problem RCU Problem
    8 low signal 12 low signal 44 low signal
    62 Oscillating 68 low signal 72 low signal
    78 low signal 82 deformed spectrum 86 low signal
    88 Oscillating 106 deformed spectrum 130 low signal
    148 low signal 150 low signal 164 low signal
    178 low signal        

    A visual inspection revealed, that the cable tie attaching one of the dipoles of antenna 106 to the ground was broken. Replacing the cable-tie fixed the deformed spectrum of antenna 106.

    Dis- and reconnecting the cables and RCU boards of antennas 62 and 88 did not remove the oscillations. So we replaced the LBAs 62/63 and 88/89. New serial numbers:

    62/63: -> LBA-24-818-00110

    88/89: -> LBA-24-818-00031