Table of contents
- 1. F192A Correlation Report
- 1.1. General information
- 1.2. Fringes
- 1.3. Notes
F192A Correlation Report
General information
- Session info: http://www3.mpifr-bonn.mpg.de/div/vlbi/globalmm/
- Station feedback: http://www3.mpifr-bonn.mpg.de/div/vlbi/globalmm/sessions/oct19/feedback_oct19.asc
Fringes
Station | Code | Fringes | Plots | Comments |
---|---|---|---|---|
Ef | B | yes | No0002_B.pdf | Effelsberg DBBC2 |
Eb | E | Effelsberg RDBE | ||
On | X | yes | No0002_X.pdf | Onsala DBBC2 v107_beta3 |
O6 | O | yes | No0002_O.pdf | |
Mh | Z | yes | No0002_Z.pdf | thick clouds and rain |
Ys | Y | yes | No0002_Y.pdf | clear skies |
Pv | P | yes | No0002_P.pdf | DBBC2 |
P3 | i | yes | No0002_i.pdf | DBBC3 backend at PV |
Notes
- Ys: LCP fringes are weaker than RCP. This could be attributed to the board serving LCP (C) not being properly calibrated. During c192b the LCP IF was switched to board B.
- P3: Phases needed to be manually alligned. SNR is comparable to DBBC2. However LL Fringes are somwhat weaker due to a drop in amplitude for the last 4 BBCs of board A. The reason for this drop needs to be investigated.
Comments