11 November

    Version as of 23:30, 22 Jul 2024

    to this version.

    Return to Version archive.

    View current version

    2012 November 15

    Olaf, Masaya and Andreas did:

    Installation of Syncoptics Boards

    Two repeater boards installed, 10 MHz clock from one port of the rubidium via tee, PPS from two ports of the rubidium.

    As the PPS and 10 MHz cables to the racks are not labeled the same rack might be connected with PPS to one
    syncoptics board and the 10 MHz clock to the other.

    Broken(?) HBA Tiles

    After installation of the syncoptics powering the station up again, the previous non-communication tiles were working fine again.

    During extensive testing some FEs of some tiles were not communicating at different times, but no really clear pattern was visible. So in the end it was decided not to exchange a FE-module, but monitor the situation longer.