F182A

    Version as of 20:27, 22 Jul 2024

    to this version.

    Return to Version archive.

    View current version

    F182A Correlation Report

    Fringes

    Station Code Fringes Plots Comments
    Ef B Yes

    Pv fringes are based on 10s of data from scan No0001:

    f182a_No0001_OJ287_BP_LL.pdff182a_No0001_OJ287_BP_RL.pdf,
    f182a_No0001_OJ287_BP_RR.pdf

    f182a_No0002_OJ287_BX_LL.pdff182a_No0002_OJ287_BX_LR.pdf,
    f182a_No0002_OJ287_BX_RL.pdff182a_No0002_OJ287_BX_RR.pdf

    f182a_No0008_1633+38_BX_LL.pdff182a_No0008_1633+38_BX_LR.pdf,
    f182a_No0008_1633+38_BX_RL.pdff182a_No0008_1633+38_BX_RR.pdf

    f182a_No0002_OJ287_BY_LR.pdff182a_No0002_OJ287_BY_RR.pdf

    f182a_No0007_1633+38_BY_LR.pdff182a_No0007_1633+38_BY_RR.pdf

    f182a_No0008_1633+38_BY_LR.pdff182a_No0008_1633+38_BY_RR.pdf

    f182a_No0002_OJ287_BZ_LR.pdff182a_No0002_OJ287_BZ_RL.pdf

    f182a_No0008_1633+38_BZ_LL.pdff182a_No0008_1633+38_BZ_LR.pdf,
    f182a_No0008_1633+38_BZ_RL.pdff182a_No0008_1633+38_BZ_RR.pdf

     
    Nearly perfect conditions: sunny, no clouds. Pointing drifts slightly, probably because the antenna is heating up in the sun. Tsys ~170K during scan No0001
    Mh Z Yes

    Pv fringes are based on 10s of data from scan No0001:

    f182a_No0001_OJ287_ZP_LR.pdf

    Clear indication of swapped pols:

    f182a_No0002_OJ287_BZ_LR.pdff182a_No0002_OJ287_BZ_RL.pdf

    f182a_No0002_OJ287_ZX_LL.pdff182a_No0002_OJ287_ZX_LR.pdf,
    f182a_No0002_OJ287_ZX_RL.pdff182a_No0002_OJ287_ZX_RR.pdf

    f182a_No0008_1633+38_BZ_LL.pdff182a_No0008_1633+38_BZ_LR.pdf,
    f182a_No0008_1633+38_BZ_RL.pdff182a_No0008_1633+38_BZ_RR.pdf

    f182a_No0008_1633+38_ZX_LL.pdff182a_No0008_1633+38_ZX_LR.pdf,
    f182a_No0008_1633+38_ZX_RL.pdff182a_No0008_1633+38_ZX_RR.pdf

    good weather. swapped pols, the setup will stay the same for c182a, but before c182b will be fixed.
    On X Yes

    Pv fringes are based on 10s of data from scan No0001:

    f182a_No0001_OJ287_XP_LL.pdff182a_No0001_OJ287_XP_LR.pdf,
    f182a_No0001_OJ287_XP_RR.pdf

    f182a_No0002_OJ287_BX_LL.pdff182a_No0002_OJ287_BX_LR.pdf,
    f182a_No0002_OJ287_BX_RL.pdff182a_No0002_OJ287_BX_RR.pdf

    f182a_No0008_1633+38_BX_LL.pdff182a_No0008_1633+38_BX_LR.pdf,
    f182a_No0008_1633+38_BX_RL.pdff182a_No0008_1633+38_BX_RR.pdf

    f182a_No0002_OJ287_ZX_LL.pdff182a_No0002_OJ287_ZX_LR.pdf,
    f182a_No0002_OJ287_ZX_RL.pdff182a_No0002_OJ287_ZX_RR.pdf

    f182a_No0008_1633+38_ZX_LL.pdff182a_No0008_1633+38_ZX_LR.pdf,
    f182a_No0008_1633+38_ZX_RL.pdff182a_No0008_1633+38_ZX_RR.pdf

    Tsys ~400K during scan No0001
    Ys Y Yes

    Fringes only to 'R'-channel:

    f182a_No0002_OJ287_BY_LR.pdff182a_No0002_OJ287_BY_RR.pdf

    f182a_No0007_1633+38_BY_LR.pdff182a_No0007_1633+38_BY_RR.pdf

    f182a_No0008_1633+38_BY_LR.pdff182a_No0008_1633+38_BY_RR.pdf

    Only in scan No0009 fringess appear also to 'L'-channel 

    f182a_No0009_1633+38_BY_LL.pdff182a_No0009_1633+38_BY_LR.pdf,
    f182a_No0009_1633+38_BY_RL.pdff182a_No0009_1633+38_BY_RR.pdf

    f182a_No0009_1633+38_XY_LR.pdff182a_No0009_1633+38_XY_RL.pdf,
    f182a_No0009_1633+38_XY_RR.pdf

    An amplifier burned out, likely just before the test. Frontend signal switched to a spare channel to compensate, but too late to influence these results. This explains low SNR, but not why we see fringes to R only (Ys normally only records LCP at 3 mm, so both 'L' and 'R' should be the same LCP)
    Pv P Yes

    Based on 10s of data from scan No0001

    f182a_No0001_OJ287_BP_LL.pdff182a_No0001_OJ287_BP_RL.pdf,
    f182a_No0001_OJ287_BP_RR.pdf

    f182a_No0001_OJ287_XP_LL.pdff182a_No0001_OJ287_XP_LR.pdf,
    f182a_No0001_OJ287_XP_RR.pdf

    f182a_No0001_OJ287_ZP_LR.pdf

    bad weather

    Notes