    5.3.2013

    Andreas reports:
    I just tested this mode (=rcumode 6) and found the following things:
    - The beamserver does not change the clock. If you set it to rcumode 6 without
      changing the clock values, then you get rcumode 6 data (i.e. 170 MHz -
      230 MHz) with the 200 MHz ADC clock, thus the data folded into one have of
      the sampled band.
    - Changing the clock does not kill the beamserver. But it does reset the
      rcumode settings of the RCUs, so you'll want to kill and restart the beam
      after changing the clock.
    - On the other hand the TBBs _are_ reseted when changing the clock. When the
      TBBDriver detects a change of the clock, it waits 80 seconds and then
      reboots the TBBs. So all data on the TBBs are lost when changing the clock.
    - To make matters worse: TBB-board number 4 (when starting to count with 0)
      does not seem to like the 160 MHz clock. When in that mode and with the RSPs
      configured to send data to the TBBs, it kept reseting every few minutes.
      (While I watched it it came back after each reset, but only until the next
      reset.)
    
    

    14.3.2013

    Test of TBBs with 160MHz clock

    Testing the clock-output of the TDS board in subrack 2 (TBBs 4 and 5) did not work, as we only brought a scope with 100MHz bandwidth.