    Points from the meeting

    1. Welcome
    2. Agenda accepted
    3. Minutes accepted
    4. AIs... (see paper)
    5. Permanent action items (reminder)
    6. Reliability and Perfomrance (Jay) (see presenetation)
      • Triangular bandpasses for some subb. e.g. Noto (DDC 16 MHz); Could there be a DDC problem?
      • N16M1 Eff no LCP; IF5R always low amp
      • low power (ca. 1/2) often for some stations (state counts fine though)
      • need feedback related to potential backend problems
      • correlate DBBC software/firmware versions in the logs against problems found (put in soon by FS?)
    7. Amplitude calibration
      • Jb bad as usual, worse than before,
      • Sh Problem
      • Good long term plots showed
      • POSTOB mechanism still possible?
    8. DBBC2
      • Gino's presentation
      • V16 needs latest test version of FS
      • Problem of 15_2 not seen
    9. Recorders
      • VDIF fits better with Ethernet output of FiLA10G
      • New features of new test version of JIVE5ab (see presentation);
        • multiple FiLA streams now possible local recording only, bookkeeping per sender,
        • tunig for very high data rate needed. see docu on web
        • scan_check: problem because of no sync word, no wall clock, degenerate bit-rate - threads, sync word of VLBA would help a little, use extended header to solve the problem?
      •