    Hardware Status as of 21. September 2011

    Electronics:

    All RCU modules plugged in.

    Some HBAs may be oscillating from time to time.

    Two LBAs were oscillating. Several LBAs with low power.

    High Band Antennas:

    All tiles are working. Two tiles (RCUs 179, 181) seem to be oscillating from time to time.

    Low Band Antennas:

    The LNAs of (the LBAs of) RCUs 74 and 112 are oscillating.

    Some (even-numbered) dipoles show little to no power in the spectrum (like as if the LNA is not working). The problem is not always consistent: some seem to recover without active intervention, some seem to recover after pulling and re-connecting the RCU.

    Date RCUs with low power in rcumode 3
    Wed 21.9.2011 8 12   542 68 72   78 82     130 1381 148 150 1521 164 178
    Thu 11.8.2011 8 12 44 54   72   78 82 86   130 1381 148 150 1521 164 178
    Fri. 8.7.2011A 8 12 44   68 72 743 78 82 86   130   148 150 1522 164 178
    Mon 4.7.2011 8 12 44     72 741 78 822 86   130   148 150   164 178
    Fri 1.7.2011A 8 12 44   68 72   78   86   130   148 150   164 178
    Wed 29.6.2011A 8   44     72   78   86 92   138 148 150   164  

    Notes:
    A No attempt to recover signal by switching rcumodes done.
    1Recovered after switching to rcumode 1 and back (a number of times)
    2Showed changing power levels.
    3 At 50-50 MHz about 10-15 dB reduced at 20 MHz about 30 dB reduced.

    Computer Status as of 21. September 2011:

    Data Taking PCs

    All data taking PCs are running.

    The RAID "/media/scratch" on lofar2 is down due to a broken disk. The disk is replaced, but the RAID is not set up yet.

    The new Dell machine(s) is installed, the LOFAR switch is said to be configured, but this needs testing.

    Server

    lofarsrv is up