C172C Correlation Report
General information
- Session info: http://www3.mpifr-bonn.mpg.de/div/vlbi/globalmm/
- Station feedback:
- OV - missing half the experiment, got scans up to No0232 and the rest are missing (got JOD+0090 JOD+0096), 10nov17 P.Perley confirmed a third OV module was found and it is now being sent to MPIfR
- KVN : fringes inside KVN within +-32usec and +-1sec; station positions and freq setup appear correct
- KVN Ky : transferred files are those of Ulsan rather than Yonsei (need to retransfer)
- KVN Kt : no fringes (asked for operator log files, the automatic log files show no error)
- Initial correlation done with all stations, second correlation (fix Effelsberg incorrect channel order) done without KVN and Mh due to local cluster data loss and stations having deleted their own copies of the data
Fringes
Station | Code | Fringes | Plots | Comments |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
Notes
Post-Correlation checks
Residuals
FITS completeness (pclist)