    F201B Correlation Report

    General information

    Fringes

    Station Code Fringes Plots Comments
    Ef B

    yes

    f201b_No0002_3C84_BX_LL.pdf, f201b_No0002_3C84_BX_RR.pdf

    f201b_No0002_3C84_BZ_LL.pdf, f201b_No0002_3C84_BZ_RR.pdf

    Effelsberg with DBBC2 backend

    it was found that there was a setup misconfiguration and the LO frequency accidentally shifted by -2 MHz. After fixing this LO offset in correlation fringes to both 

    Eb E yes  

    Effelsberg with RDBE backend

    It was added in in attempt to help in investigating the problems, unfortunately misconfigured to 4 x 64 MHz per pol instead of its supposed 4 x 128 MHz per pol. Possibly there were other setup problems. Only zero-baseline fringes EfEb were found.

    On X yes f201b_No0002_3C84_BX_LL.pdf, f201b_No0002_3C84_BX_RR.pdf OK
    Mh Z yse f201b_No0002_3C84_BZ_LL.pdf, f201b_No0002_3C84_BZ_RR.pdf OK