Table of contents
- 1. F191A Correlation Report
- 1.1. General information
- 2. Purpose
- 2.1. Fringes
- 2.2. Notes
- 2.3. Post-Correlation checks
- 2.3.1. Residuals
- 2.3.2. FITS completeness (pclist)
F191A Correlation Report
General information
- Session info: http://www3.mpifr-bonn.mpg.de/div/vlbi/globalmm/
- Station feedback: http://www3.mpifr-bonn.mpg.de/div/vlbi/globalmm/sessions/apr19/feedback_apr19.asc
Purpose
- 4 Gbps test of the GMVA.
- For setup details see: 4GbpsTest Page
Fringes
Scan 7, 3C454.3, baselines including only EVN stations: f191a_No0007_3C454.3_EVN.pdf
Scan 7, 3C454.3, baselines including only VLBA stations: f191a_No0007_3C454.3_VLBA.pdf
Scan 7, 3C454.3. baselines including an EVN and a VLBA station: f191a_No0007_3C454.3_mixed_EVN_VLBA.pdf
Scan 7, all baselines, including autocorrs: No0007_all.pdf
... same, but fringes searched for each of 16 channels separately:
No0007_ch_a.pdf, No0007_ch_b.pdf, No0007_ch_c.pdf, No0007_ch_d.pdf,
No0007_ch_e.pdf, No0007_ch_f.pdf, No0007_ch_g.pdf, No0007_ch_h.pdf,
No0007_ch_i.pdf, No0007_ch_j.pdf, No0007_ch_k.pdf, No0007_ch_l.pdf,
No0007_ch_m.pdf, No0007_ch_n.pdf, No0007_ch_o.pdf, No0007_ch_p.pdf.
For this scan, SNRs and amplitudes of EfPv. EfP3, OnPv and OnP3 baselines compared: EfOnPvP3_by_chan.pdf
Station | Code | Fringes | Plots | Comments |
---|---|---|---|---|
Ef | B | Yes | Europe only: No0007_B.pdf, also see plot collections before the table | |
Pv | P | Yes | Europe only: No0007_P.pdf, also see plot collections before the table | Pico Veleta DBBC2 |
P3 | i | Yes | Europe only: No0007_i.pdf, also see plot collections before the table | Pico Veleta DBBC3 |
Ys | Y | Yes | Europe only: No0007_Y.pdf, also see plot collections before the table | |
On | X | Yes | Europe only: No0007_X.pdf, also see plot collections before the table | |
Mh | Z | Yes | Europe only:No0007_Z.pdf, also see plot collections before the table | |
Br | b | Yes | f191a_No0007_3C454.3_bl_LL.pdf, f191a_No0007_3C454.3_bl_LR.pdf, f191a_No0007_3C454.3_bo_LL.pdf, f191a_No0007_3C454.3_bo_RR.pdf, also see plot collections before the table | |
Fd | f | Yes | see plot collections before the table | |
Kp | k | Yes | f191a_No0007_3C454.3_kp_LL.pdf, f191a_No0007_3C454.3_kp_LR.pdf, also see plot collections before the table
| |
La | l | Yes | f191a_No0007_3C454.3_bl_LL.pdf, f191a_No0007_3C454.3_bl_LR.pdf, f191a_No0007_3C454.3_lo_LL.pdf, f191a_No0007_3C454.3_lo_LR.pdf, also see plot collections before the table
| |
Mk | m | |||
Nl | n | |||
Ov | o | Yes | f191a_No0007_3C454.3_bo_LL.pdf, f191a_No0007_3C454.3_bo_RR.pdf, f191a_No0007_3C454.3_lo_LL.pdf, f191a_No0007_3C454.3_lo_LR.pdf, also see plot collections before the table
| |
Pt | p | Yes | f191a_No0007_3C454.3_kp_LL.pdf, f191a_No0007_3C454.3_kp_LR.pdf, also see plot collections before the table
| |
__________________________________________________________________ |
Notes
- Data format VLBA: INTERLACEDVDIF/0:1:2:3:4:5:6:7/5032/2
- Data format Pv, Ef, On: DBBC2-astro
- Data format Ys, Mh: DBBC2-astro2
- Data format P3: BBC1-U,BBC1-L,BBC2-U,BBC2-L,....
- P3: Fringe SNR generally lower than with Pv-DBBC2. Autocorrelation bandshape suspect (DBBC2 reference, vs. DBBC3). Needs to be investigated
- The scan with DBBC3 has 299.796 s of data while the DBBC2 scan has only 296.645 s. This may explain a few minor discrepancies. I suggest to FF with cutting at the end and beginning of the scan so that we will have exactly the same data for both.
- Data weights for VLBA stations < 1.000
30.83% 0.917 1.000 0.816 0.890 0.895 1.000 1.000 0.924 1.000 1.000 0.882 1.000 ERROR Lost Sync on segment 0! Will attempt to resync. Deltatime was -0.498s Thu Sep 12 14:01:32 2019 MPI[ 6] io02 f191a_7 DEBUG Corrday was 58577, corrsec was 46500. MJD was 58577, sec was 46589> Readseconds was 88.