Y191A: PV - YS test (Ys dual-pol receiver)

    Version as of 19:08, 16 Apr 2024

    to this version.

    Return to Version archive.

    View current version

    Y191A Correlation Report

    General information

    • The purpose of this observation was to test the new Ys dual-pol receiver

    Status

    Parts of a few scans were correlated, test is a success.

    Fringes

    Baseline Code Fringes Plots Comments
    Pv-Ys PY Yes

    New dual-pol receiver:

    Scan No0003:

    y191a_No0003_3C345_PY_LL.pdf
    y191a_No0003_3C345_PY_LR.pdf
    y191a_No0003_3C345_PY_RL.pdf
    y191a_No0003_3C345_PY_RR.pdf

    Scan No0009:

    y191a_No0009_3C84_PY_LL.pdf
    y191a_No0009_3C84_PY_LR.pdf
    y191a_No0009_3C84_PY_RL.pdf
    y191a_No0009_3C84_PY_RR.pdf

    Returned to old single-pol receiver (RCP duplicates the LCP signal)

    Scan No0010:

    y191a_No0010_3C84_PY_LL.pdf
    y191a_No0010_3C84_PY_LR.pdf
    y191a_No0010_3C84_PY_RL.pdf
    y191a_No0010_3C84_PY_RR.pdf

    Strong parallel-hand fringes, no or weak cross-hand fringes. SNR of RR fringe is somewhat larger than the one for LL fringe.

    The amplitude vs channels plots of both LL and RR exhibit a strange "bowl" shape, with amplitudes in edge channels up to 4 times higher than the amplitude in the central ones.

    After the return back to the old single-pol receiver the problem persists (see LL and LR plots of scan No0010).

    Notes