F251A Correlation Report

    General information

    Status

    what date
    DBBC2 test conducted successfully 25.04.2025
    DBBC3 test conducted successfully 29.04.2025
    Started transfer of rest of scans: Mh done, On done, Od check, Yd 12.05.2025
       

    FFringes

    Station Code Fringes Plots Comments
    Ef B y No0011_B.pdf  
    Pv P y No0011_P.pdf  
    On X y No0005_X.pdf  
    Mh Z y No0005_Z.pdf  
    Nn N y No0001_N.pdf  
    Ys Y y No0005_Y.pdf  
    Od L y No0011_L.pdf  
    Yd W y No0011_W.pdf  
    Ed F y No0011_F.pdf  

    Notes

    SNR B F L W X Y
    B - - 100 45 120 55
    F - - 80 35 120 45
    L 100 80 - 30 - 30
    W 45

    35

    30 - 28 -
    X 120 120 - 28 - 50
    Y 55 45 30 - 50 -

    Average SNR for parallel hands for SCAN No0011.

    Post-Correlation checks

    Residuals

    FITS completeness (pclist)